What is SCADA? Questions and answers
Short, plain answers to the questions people ask most about SCADA, from what the letters mean to how a career in it starts. This page goes with the five-minute video What is SCADA?
The basics
What does SCADA stand for?
Supervisory Control and Data Acquisition. Data acquisition means gathering measurements from equipment spread across a plant, a city or a whole region. Supervisory control means operators can act on that equipment from one central place.
What does a SCADA system actually do?
It watches equipment that is too spread out for anyone to stand beside, keeps a record of everything it sees, and lets a person step in: change a setpoint, start a pump, open a breaker. A water utility, for example, uses SCADA to bring its wells, treatment plant, tanks and lift stations onto one screen.
Where is SCADA used?
Water and wastewater, electric power, oil and gas pipelines, manufacturing, mining, transportation and building automation. A good rule of thumb: if it's spread out and it matters, SCADA is probably watching it.
How it works
What are the layers of a SCADA system?
From the bottom up: field instruments (sensors and actuators), controllers (PLCs and RTUs), communications, the SCADA server, and on top the HMI, alarms and the historian.
What are sensors and actuators?
Sensors measure the process: level, pressure, flow and temperature. Actuators do the work: pumps, valves, motors and breakers.
What is the difference between a PLC and an RTU?
Both are controllers wired to the field instruments. A PLC (programmable logic controller) is built for fast, local control, often inside a plant. An RTU (remote terminal unit) is built for remote sites: low power, rugged, and good at talking over slow links. Today the line between them is blurry, and many remote sites run a PLC.
Learn the logic side in PLC Ladder Logic Fundamentals.
Does SCADA control the process?
Not directly. The controller does the controlling; SCADA supervises. If the tank is high, the PLC stops the pump on its own. If the network drops, the PLC keeps running its site. SCADA watches, records, and lets a person change what the controller is doing.
How does SCADA talk to remote sites?
Over almost any link: copper, fiber, licensed radio, cellular or satellite. Some sites are fifty miles from the nearest road, so the link is often slow or unreliable, and SCADA is designed around that.
Which protocols does SCADA use?
Modbus is the simplest and the most common. DNP3 is the workhorse of water and electric utilities. IEC 61850 runs modern substations. OPC UA ties systems from different vendors together.
Go deeper with Understanding Modbus, Understanding IEC 61850 MMS and Understanding TCP/IP.
What are polling and report by exception?
With polling, the SCADA server asks each controller for its values on a schedule. With report by exception, the device sends a value only when it changes, which saves bandwidth on slow links. Many systems use both.
What is a tag?
A tag is one data point in SCADA, like a tank level or a pump's run status. Every tag carries a value, a quality (can the value be trusted?) and a timestamp.
What is an HMI?
The human-machine interface: the screens operators use. Good screens show the process the way it really flows (tanks filling, pumps running, valves open or closed) with the numbers that matter right beside them.
Build your own with Getting Started With Ignition.
How do SCADA alarms work?
When something goes wrong, such as a high level, a failed pump or a lost connection, the alarm system tells the operator. Each alarm has a priority, so the most dangerous problem is handled first. The operator acknowledges it and moves on.
Too many alarms are their own problem; see Alarm Rationalization by the Numbers.
What is a historian?
A database that stores every value with its time, for months or years. Engineers use it to spot a pump wearing out, prove compliance to regulators, and replay exactly what happened during an upset.
Context
What is the difference between SCADA and a DCS?
A DCS (distributed control system) usually runs one large plant, like a refinery, with control tightly integrated. SCADA usually spans distance: many sites over slow or unreliable links. The lines have blurred, but the instinct is still useful.
How has SCADA changed over time?
The first systems, in the 1960s and '70s, were mainframes with proprietary radios. Then came networked servers. Today SCADA runs on standard IT, with web-based screens and cloud-connected data.
Is SCADA a cybersecurity risk?
It can be. SCADA controls physical things, so an attacker can do physical harm. Good systems use defense in depth: segmented networks, firewalls, secure remote access, and standards like ISA/IEC 62443.
See the Ethical Hacking series.
What jobs are there in SCADA?
Instrument technicians who wire and test the field devices, PLC programmers who write the control logic, and SCADA engineers who build the screens, alarms and networks that tie it together. For hiring managers and recruiters, Speaking SCADA explains the field in business terms.